XXV Pellet Stove
The room sensor is a small temperature sensor
on the end of a 60" wire. This sensor is installed
much like a standard wall thermostat. Because
it is so small, it can be hidden along the trim of a
doorway or even up the leg of a coffee table. There
is a remote room sensor port on the rear of the
unit for easy external connection. Use standard
18-2 thermostat wire to extend the distance to the
desired location (50' maximum). The room sensor
should be installed in the location where you want
to control the temperature.
In most installations locating the room sensor
behind the stove near the distribution fan works
well because the sensor monitors the room air
being drawn into the distribution fan.
Distances of more than 25 feet from the
unit or in another room are not recommended. The
room sensor is essential for the XXV's excellent
efciency.
 