XXV Pellet Stove

 This setting, see above,
will produce a room temperature of 70 degrees with the
distribution blower at medium speed.
The XXV is a fully automatic stove that features
two operating modes;  and
  . In Stove Temperature
Mode, you select a burn rate and the stove will remain at
the same burn rate regardless of the room temperature.
In the Room Temperature Mode the stove constantly
monitors the temperature in the room and adjusts the
size of the re and the heat output of the stove so that
the room is kept at a constant temperature. Room
Temperature Mode, in the AUTO position, has the
added advantage of turning the stove off if no heat
is required and turning the stove on again when the
room temperature drops below your desired room
temperature set point.

Most consumers use the stove in the Room
Temperature Mode because it is the easiest and
most efcient method of keeping the room at a given
temperature. In the Room Temperature Mode, the
Room Sensing Probe constantly monitors room
temperature. As the weather changes outside and
your home needs varying amounts of heat to be at a
desired temperature, the stove will automatically adjust
size and heat output of the re so that a constant even
temperature is maintained. If the weather warms
up and no heat is required the stove will gradually
shut down. When the house cools down, the stove
will automatically bring the room temperature to your
desired setting
In the Room Temperature Mode you can select either
 for the  using the igniter
toggle switch. When the toggle switch is in the Auto
position the igniter, located inside the burn pot, is ready
to automatically light the re when required. When the
toggle switch is set to the Manual position, the stove
can be lit manually with either a gel or a wax type re
starter. (see lighting instructions on page 20.) With the
igniter toggle switch set in the Manual position the stove
will automatically adjust the heat output, but the stove
will not automatically shut down if no heat is required.
Instead it will go to its lowest setting and remain there.
The Manual position on the igniter toggle switch lets
you light the stove manually, should the igniter fail for
any reason. Secondly, if you are using the Harman
battery back up system the Manual setting will prevent
the stove from turning off and on during a power failure,
which will drain the back up battery, and possibly cause
damage to the back-up or the stove.
In the Room Temperature Mode, the distribution
blower speed can be increased or decreased by
adjusting the Room Temp/Off/Stove Temp dial between
L and H. As output of the stove increases, the speed
of the blower will increase automatically to ensure
that more heat is transferred out into the room. The
distribution blower will shut off as the room reaches
the set temperature, this will prevent overheating of
the room.
