Dry Seasoned Wood Only! 3-90-08560 Save These Instructions


Minimum Size oor protection (USA) is 48" Deep By
32.5" Wide.

If the appliance is being installed on a combustible
oor, non-combustible oor protection must be installed.
In all installations, the area under and around the stove
must be protected from falling ash and live coals. The
area under a horizontal run of chimney connector must
also be protected, extending two (2) inches (51mm) to
each side of the horizontal connector.
Further guidelines for oor protection are as follows:
In the U.S. the oor protector must be completely under
the stove, and extending 18" in front of the door opening,
8" to each side of the door opening, and 8" to the back.
In Canada, the floor protection must extend 18"
(457mm) in front of the door opening, and 8" (203mm)
to each side of the appliance, and to the rear.



* Floor protection dimensions for the front and sides
are measured from the appliance door opening in
The United States. In Canada, the side dimension is
measured from the widest part of the appliance.


Inches Millimeters
Sides- USA /CANADA *
Rear- USA
8 203
8 203
Rear- CANADA
8 203
Front- USA /CANADA *
18 457
The recommended oor protection for a corner
installation is 60" (USA & CANADA).