Harman Stove Company HARMAN Super Magnum Coal Stoker Stove User Manual

Browse online or download User Manual for Stoves Harman Stove Company HARMAN Super Magnum Coal Stoker Stove. Harman Stove Company HARMAN Super Magnum Coal Stoker Stove User's Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 40
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
3-90-02702R4_08/12
www.harmanstoves.com
Owner's Manual
Installation and Operation
Model:
Super-Magnum
Coal Stoker Stove
NOTICE
Important operating and
maintenance instructions
included.
Read, understand and
follow these instructions
for safe installation and
operation.
Leave this manual with
party responsible for use
and operation.
Please read this entire manual
before installation and use of this
coal-burning room heater.
Failure to follow these instructions
could result in property damage,
bodily injury or even death.
Do not store or use gasoline or other ammable
vapors and liquids in the vicinity of this or any other
appliance.
Do not overre - If any external part starts to glow,
you are overring. Reduce feed rate. Overring
will void your warranty.
Comply with all minimum clearances to
combustibles as specied. Failure to comply may
cause a house re.
Check building codes prior to installation.
Installation MUST comply with local, regional, state and
national codes and regulations.
Consult local building, fire officials or authorities having
jurisdiction about restrictions, installation inspection, and
permits.
Hot, will cause burns.
Do not touch glass until it is cooled
NEVER allow children to touch glass
Keep children away
CAREFULLY SUPERVISE children in same room as
replace.
Alert children and adults to hazards of high temperatures.
High temperatures may ignite clothing or other
ammable materials.
Keep clothing, furniture, draperies and other ammable
materials away.
HOT SURFACES!
Glass and other surfaces are
hot during operation AND
cool down.
WARNING
CAUTION
Tested and approved for use with anthracite "rice"
coal only. Burning any other type of fuel will void
your warranty.
DO NOT DISCARD THIS MANUAL
WARNING
CAUTION
Do Not
Discard
Page view 0
1 2 3 4 5 6 ... 39 40

Summary of Contents

Page 1 - Owner's Manual

3-90-02702R4_08/12 www.harmanstoves.comOwner's ManualInstallation and OperationModel:Super-

Page 2 - A division of

10Super-Magnum Coal Stoker StoveDo Not Burn Wet Coal!3-90-02702R4_08/12 B. Clearances To Combus

Page 3 - TABLE OF CONTENTS

11Do Not Burn Wet Coal!Super-Magnum Coal Stoker Stove3-90-02702R4_08/12 5 Chimneys and VentingA.

Page 4 - Listing and Code Approvals

12Super-Magnum Coal Stoker StoveDo Not Burn Wet Coal!3-90-02702R4_08/12 D. The ChimneyThis unit

Page 5 - SPECIAL NOTE:

13Do Not Burn Wet Coal!Super-Magnum Coal Stoker Stove3-90-02702R4_08/12 Do not burn any fuel oth

Page 6 - Getting Started

14Super-Magnum Coal Stoker StoveDo Not Burn Wet Coal!3-90-02702R4_08/12 E. Draft Test Procedure

Page 7 - C. Component Locations

15Do Not Burn Wet Coal!Super-Magnum Coal Stoker Stove3-90-02702R4_08/12 6 Mobile HomeA. Mobile

Page 8 - D. Pre- Use Check List

16Super-Magnum Coal Stoker StoveDo Not Burn Wet Coal!3-90-02702R4_08/12 7 Appliance Set-UpA. Ou

Page 9 - Dimensions & Clearances

17Do Not Burn Wet Coal!Super-Magnum Coal Stoker Stove3-90-02702R4_08/12 B. Leveling the Applian

Page 10 - Inches Millimeters

18Super-Magnum Coal Stoker StoveDo Not Burn Wet Coal!3-90-02702R4_08/12 F. Optional Door Trim K

Page 11 - Chimneys and Venting

19Do Not Burn Wet Coal!Super-Magnum Coal Stoker Stove3-90-02702R4_08/12 8 Operating Instruction

Page 12

2Super-Magnum Coal Stoker StoveDo Not Burn Wet Coal!3-90-02702R4_08/12 Hearth & Home Technol

Page 13 - Do Not Burn Wet Coal!

20Super-Magnum Coal Stoker StoveDo Not Burn Wet Coal!3-90-02702R4_08/12 Status Light Error Messa

Page 14 - E. Draft Test Procedure

21Do Not Burn Wet Coal!Super-Magnum Coal Stoker Stove3-90-02702R4_08/12 a. Feed Rate AdjustmentT

Page 15 - Mobile Home

22Super-Magnum Coal Stoker StoveDo Not Burn Wet Coal!3-90-02702R4_08/12 C. Before Your First Fi

Page 16 - Appliance Set-Up

23Do Not Burn Wet Coal!Super-Magnum Coal Stoker Stove3-90-02702R4_08/12 Symptom Possible

Page 17 - D. Air Filter

24Super-Magnum Coal Stoker StoveDo Not Burn Wet Coal!3-90-02702R4_08/12 10 Service & Mainte

Page 18 - G. Room Sensor Installation

25Do Not Burn Wet Coal!Super-Magnum Coal Stoker Stove3-90-02702R4_08/12 2. Heat Exchanger Chain

Page 19 - Operating Instructions

26Super-Magnum Coal Stoker StoveDo Not Burn Wet Coal!3-90-02702R4_08/12 3. Fines Tray Emptying•

Page 20

27Do Not Burn Wet Coal!Super-Magnum Coal Stoker Stove3-90-02702R4_08/12 5. Air Filter• Frequenc

Page 21

Super-Magnum Coal Stoker StoveDo Not Burn Wet Coal!3-90-02702R4_08/12 288. Chimney Connector• F

Page 22 - E. Fire Characteristics

29Do Not Burn Wet Coal!Super-Magnum Coal Stoker Stove3-90-02702R4_08/12 3. Distribution BlowerRe

Page 23 - Troubleshooting

3Do Not Burn Wet Coal!Super-Magnum Coal Stoker Stove3-90-02702R4_08/12 TABLE OF CONTENTSSection

Page 24 - Service & Maintenance

30Super-Magnum Coal Stoker StoveDo Not Burn Wet Coal!3-90-02702R4_08/12 11 Reference Materials1

Page 25

Service PartsSuper Mag StokerPart number list on following page.1-90-02700-1Beginning Manufacturing Date: July 2009 Ending Manufacturing Date: Active3

Page 26 - (removed)

Service PartsIMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement parts for your appliance please provide model number and ser

Page 27

Service PartsIMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement parts for your appliance please provide model number and ser

Page 28 - D. Motors and Components

Service PartsIMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement parts for your appliance please provide model number and ser

Page 29 - ESP (probe)

Service PartsSuper Mag StokerBeginning Manufacturing Date: July 2009 Ending Manufacturing Date: ActiveIMPORTANT: THIS IS DATED INFORMATION. When reque

Page 30 - Reference Materials

4021-645C 12-29-10 Page 1 of 2Hearth & Home Technologies Inc.LIMITED LIFETIME WARRANTYHearth & Home Technologies Inc., on behalf of its heart

Page 31 - Super Mag Stoker

4021-645C 12-29-10 Page 2 of 2WARRANTY CONDITIONS:• This warranty only covers HHT appliances that are purchased through an HHT authorized dealer or

Page 32

38Super-Magnum Coal Stoker StoveDo Not Burn Wet Coal!3-90-02702R4_08/12 Service & Maintenanc

Page 33

39Do Not Burn Wet Coal!Super-Magnum Coal Stoker Stove3-90-02702R4_08/12 Service & Maintenanc

Page 34

4Super-Magnum Coal Stoker StoveDo Not Burn Wet Coal!3-90-02702R4_08/12 1 Listing and Code Approv

Page 35

Proudly Printed On 100% Recycled PaperAt Harman, we build each product to a standard, not a price. (Signature of Boxer)Your premium quality hearth pro

Page 36 - WARRANTY PERIOD:

5Do Not Burn Wet Coal!Super-Magnum Coal Stoker Stove3-90-02702R4_08/12 NEVER CONNECT THIS UNIT T

Page 37 - WARRANTY EXCLUSIONS:

6Super-Magnum Coal Stoker StoveDo Not Burn Wet Coal!3-90-02702R4_08/12 3 Getting StartedA. Desig

Page 38 - Service & Maintenance Log

7Do Not Burn Wet Coal!Super-Magnum Coal Stoker Stove3-90-02702R4_08/12 C. Component LocationsLo

Page 39

8Super-Magnum Coal Stoker StoveDo Not Burn Wet Coal!3-90-02702R4_08/12 D. Pre- Use Check List1.

Page 40 - (Signature of Boxer)

9Do Not Burn Wet Coal!Super-Magnum Coal Stoker Stove3-90-02702R4_08/12 4 Dimensions & Cleara

Comments to this Manuals